Devoted to making better vibration plates

Vibration Noise of VT007

Vibration plates produce mechanical noises due to the friction and impact among moving parts and assemblies. When vibrated, assembled parts can become more or less loose and impact each other to produce mechanical noises. Resonance effect amplifies the noise level if the structure and materials are not well designed.

VT007 is re-invented from our popular VT003F linear vibration plate. The design concept is to minimize the number of assemblies that subject to vibration. With far less parts count, separation of the control box, optimized structure and refined materials, VT007 has achieved significant reduction of mechanical noise. Especially the annoying high pitch noises are mostly eliminated, left mainly low level noise from the bearings and low frequency sound wave.

VT007 is probably the quietest linear vibration plate model in the market, with comparable vibration intensity.

VT007 Vibration Plate Noise Measurement

vibration plate noise
Sound Level Meter:
RISEPRO Sound Level Meter
Frequency Range: 31.5Hz-8KHz
Measuring Range: 30-130dB
Frequency Weighting: A
Resolution: 0.1 dBA
Samples:
The testing samples are 6 units of VT007 High Frequency Vibration Plates randomly selected from one production batch (2021 version)
Source:
The source is selected at the center of the footplate (right above the motor).
Distance from Noise Source:
The sound level meter is placed 6 inches above the machine.

Below are the measurement results.

VT003F Vibration Plate Noise Level Measurement
Frequency Amplitude Lo Amplitude Hi
15 Hz 42 - 43 dBA 42 - 44 dBA
20 Hz 43 - 45 dBA 44 - 46 dBA
25 Hz 49 - 52 dBA 48 - 52 dBA
30 Hz 50 - 53 dBA 54 - 59 dBA
35 Hz 52 - 54 dBA 56 - 60 dBA
40 Hz 55 - 57 dBA 56 - 62 dBA

Maximum noise level measured on VT007 is between 56 dBA and 62 dBA, at the highest vibration frequency (40Hz) and Hi amplitude setting.

In terms of loudness and annoyance factor, human ears perceive the same dBA level differently depending the frequency. For example, 50 dBA at 30Hz sounds much louder than 50 dBA at 20Hz.

Not just that VT007 produces less noise in dBA level, more importantly is that VT007 has largely eliminated high frequency mechanical noises. Therefore the noise from VT007 is much less annoy.

Noise Level Comparisons

Environment (dBA)
Quite basement 20
Living room 40
Library 40
Large office 50
Freeway traffic 70
Heavy traffic 85
Busy restaurant 85
Electric Appliances (dBA)
Refrigerator 50-55
Electric toothbrush 50-60
Washing machine 50-75
Dishwasher 55-70
VT007 @ Max 56-62
Vacuum Cleaner 60-85
Hair dryer 60-95

Comments & Discussions
© 2017 - 2024 Vibration Therapeutic® All rights reserved.